Foundation granular bedding calculator
Estimate compacted and loose bedding quantities beneath rectangular foundations.
Calculation method
Compacted volume = length × width × compacted depth × count. Loose order volume = compacted volume × loose-to-compacted factor.
Worked example
Ten 4 m × 3 m bedding areas at 150 mm depth give 18 m³ compacted and 21.6 m³ loose at a factor of 1.2.
Scope and assumptions
Enter dimensions and conversion factor from the project specification or supplier. The result covers a uniform layer and excludes excavation and blinding.