TrendyBuilders logoTrendyBuilders
Open workspace ↗
← Engineering Calculators

Retaining wall drainage aggregate calculator

Estimate aggregate volume and the back face area covered by a drainage zone behind a retaining wall.

Calculation method

Multiply length by average height for the back face area. Multiply by the drainage zone width for in-place volume, then apply the entered percentage for the allowance-adjusted volume.

Worked example

A 25 m wall with a 2.4 m high and 0.3 m wide drainage zone gives 60 m² of back face area, 18 m³ in place and 18.9 m³ with 5% allowance.

Scope and assumptions

Measure the drainage zone from the drawings. Quantify drain pipes, filter layers, geotextile laps and returns separately. Use supplier-specific volume conversion when ordering loose aggregate.