Retaining wall geogrid quantity calculator
Estimate geogrid area across identical full-width reinforcement layers from a specified layout.
Calculation method
Multiply wall length by geogrid depth and layer count. Apply the entered allowance to get the procurement area.
Worked example
Five layers each measuring 24 m × 3.5 m require 420 m² net. An 8% allowance gives 453.6 m².
Scope and assumptions
Use reinforcement dimensions from the approved layout. Confirm roll direction, overlaps and roll counts against the supplier layout before ordering.