TrendyBuilders logoTrendyBuilders
Open workspace ↗
← Engineering Calculators

Round column concrete and formwork calculator

Measure circular concrete columns and curved side formwork from scheduled diameter and height.

Calculation method

Multiply circular cross-sectional area by height and count for concrete. Multiply circumference by height and count for side forms.

Worked example

Ten columns at 500 mm diameter and 3 m height require about 5.890 m³ of concrete and 47.124 m² of side forms.

Scope and assumptions

Use one uniform circular section per calculation. Top and bottom faces and local deductions are measured separately.